- Product Description
- Company Profile
mega serie portable gaz sf6 _Indoor AC Metal-Clad Switchgear (KYN10-40.5)
KYN 10-40.5 type AC metal-clad switchgear (hereafter referred to as “switchgear”) is a kind of complete indoor
type with three phases, 50Hz, AC and single busbar system, used in 35kV net for power transmission and
distribution.
Product feature:
It is a metal-clad type of switchgear, and it consists of two components, one is main body welded by sectioned
steel and bent steel plate and another component is truck. It is the latest self-designed and developed version
of switch by introduction of advanced technology in domestic and abroad. With advantages of a smaller size, a
big breaking current, easier installation, a long-free-maintenance duration, this kind of switchgear has
characters of easy operation and maintenance, safe operation, five-protection function and inter-lock capacity,
etc as well.
Note 1. The width of the cubicle is 1700
The packing size (width*depth*height) (mm) 2020*2380*2870
Ordering notice:
A. Please provide primary main wiring system diagram, layout plan, principle diagram of secondary circuit and
terminal pareto diagram;
B. Type, specification, quantity and technical parameter of primary and secondary elements of the switchgear;
C. Color of cubicles, if not special requirement, up to manufacturer standards;
D. If over-voltage protection apparatus is needed, please indicate it;
E. Please indicate that if the switchgear is used on the special condition;
F. Any other requirements from users could be negotiated.
Technical parameters:
Rated voltage (kV) | 40.5 | ||
Rated current (A) | 1250,1600 | ||
Rated short circuit breaking current (KA) | 25,31.5 | ||
Rated peak withstand current (peak) (KA) | 63,80 | ||
4s short time withstand current (KA) | 25,31.5 | ||
Rated insulation level | 1min power frequency withstand voltage (KV) | Phase to earth£¬phase to phase | 95 |
Isolating distance | 118 | ||
Lightning impulse withstand voltage(kV) | Phase to earth, phase to phase | 185 | |
Isolating distance | 215 | ||
Fitted in circuit breaker |
Vacuum circuit breaker, SF6 circuit breaker | ZN12-40.5 ,ZN23-40.5 ,3AH (SIEMENS) Type FP (ALSTOM), LN2 serial |
|
Dimension (width*depth*height) (mm) |
1400x2200x2725 (welding) 1400x2210x2725 (assembly)(note1) |
||
packing Dimension(width*depth*height)(mm) | 1720x2380x2870 (note 2) |
||
Weight(circuit breaker cubicle)(kg) | 1700 (including 600,weight of truck) | ||
Protection degree | IP2X |
Our Services
1. | Pre sale service |
a. | make technical solution |
b. | send quotation, technical data sheet and drawing |
c. | prepare power transmission plan, testing plan and shipment plan |
2. | In sale service |
a. | supervise the manufacturing schedule totally in accordance with the plan |
b. | send photos to customer during every manufacturing process(hold point) |
c. | inform the customer one week before testing. |
3. | After sale service |
a. | installation and commissioning, training the workers |
b. | quick response within 12 hours any time |
c. | provide 12 months guarantee period normally. |
FAQ
1. Q: | What is your delivery time ? |
A: | Depend on the type of transformer. |
2. Q: | What is your payment term? |
A: | 30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it. |
3. Q: | What kind of standard you follow? |
A: | IEC, ANSI, CSA, GB, etc |
4. Q: | What kind of supporting documentation you can provide normally |
A: | Quotation, outline drawing, manufacturing plan, quality control plan testing plan, financial report, type test report(KEMA, CESI),reference list, etc |
5. Q: | What is your normal warranty period? |
A: | 12 months after transformer operation. |
6. Q: | Can u do installation and commission in user’s site? |
A: | Yes, we can send our installation team to user’s country for service. |
7. Q: | Do you have any experience in this kind of transformer? |
A: | Yes, we can provide reference list for check. |
Our advantages:
Quality Assurance
–From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
–With more than 30 years’ experience in power industry, VILLE brings you an optimized solution.
Global Service
–Wherever you are, VILLE global network will support and provide you with value.
Quick Response
–In response to your needs without delay, VILLE knows the value of your time.
Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!
b057r03 filter sf6 газ _Rsc3000 Series Sf6 Gas Vacuumizing and Refilling Device
Product Introduction
RSC3000 series SF6 gas vacuumizing and refilling device is mainly used for installation, commissioning and maintenance of SF6 circuit breaker,SF6 transformer,GIS and other SF6 Electrical products.
Technical parameters
Vacuum pumping rate:customized
Vacuum time:according to vacuum pumping rate
Ultimate vacuum:<10Pa
Leakage rate:<0.5%
Transmission pipe:5m
Vacuum meter:pointer or digital
Power supply:380~460VAC 50Hz
1000kv Porcelain Hollow Core Insulator for Substations Price_ dn8 purchase sf6 가스
- Product Description
- Company Profile
66kv to 500kv Bushing Current Transformer for Gis_ l170r01 liquefy sf6 가스
Application:
The Outdoor Mounted Bushing Current Transformer is self contained and designed to be mounted externally over the high voltage terminal bushing of 66kv to 500kv Power transformers, 66kv to 500kv Power circuit breakers and 66kv to 500kv Cable terminators .
In most cases the BCT, with its ease of installation, is a reliable and economical solution when upgrading system protection and adding additional metering points.
When properly installed, the BCT can be used on higher system voltage levels while maintaining its own mere 600 Volt class rating. Its simple construction provides a low leakage product with virtually unlimited short circuit capabilities, far surpassing its stand alone wound-type counterpart
.
Construction:
The toroidal core is continuously tape wound using cold rolled grain oriented electrical grade silicon steel, which receives a full stress relief anneal after it is wound to its specified dimensions. The secondary winding is then wound of insulated copper magnet wire over the insulated core with the turns equally spaced around the core periphery. When taps are pulled, they are wound in a manner that assures a fully distributed winding between any connections. The coil is then fully encapsulated in an ANSI 70 (sky grey) resin system that has been developed and tested for outdoor use. The potting compound is U.V. stabilized, is flexible to allow for expansions caused by temperature variations from -50°C to +65°C, has good chemical resistance, high dielectric strength, rugged physical properties to endure mechanical shock, and overall excellent weather resistance.
Installation:
The BCT is custom designed to fit over any bushing. It can be supported by mounting clamps with standard bolt arm assembly & hardware for vertical adjustment. The placement of the bolts can be configured from either the ID or OD, and attached to the apparatus tank top. The number of clamps required is dependent on physical size and weight of the BCT. Custom mounting that permits attachment of clamping brackets directly to the bushing flange can also be provided – consult the factory for this option. In addition, a custom fitted ground shield may be installed on the top of the BCT and secured by the mounting clamps. This is highly recommended to direct any possible flash-over to the ground, thus bypassing the BCT preventing destruction of the BCT and connected equipment. Installation instructions are provided.
Handling and Storage:
For domestic shipments, the BCT is usually palletized with spacers between the units and the pallet to allow for lifting. Ideally they should be lifted using endless slings in a 2-point or 3-point arrangement, lifting by fork lift or overhead hoist, one unit at a time. Caution should be employed while moving to avoid damaging or chipping the insulation, and, any sudden impacts to the unit or the conduit box. The units are outdoor rated so they may be left outside as originally packaged, but they should preferably be stored indoors until ready for use. Pallets should not be stacked.
Size Selection:
Each unit is custom designed for its application. In addition to the current ratio, accuracy class and power frequency, some information regarding the equipment must be provided. Since there are countless configurations of equipment in the field, a site survey is recommended to aide with the proper sizing of the BCT. Often OEM outline drawings do not provide enough detail to determine this. We suggest submitting the original bushing drawing, digital photographs of each terminal and its immediate surroundings, and if possible some field measurements to locate potential obstacles such as conduit runs, oil gauges, manhole covers, lifting lugs, etc. Meramec Engineering will lay out the details using tools that will verify the size and strike clearances. Installation drawings will be provided for all custom mounted installations.
eu 517 contain hexafluorure de soufre _Gas-Insulated Voltage Transformer /Transformer Parts PT / PT Product High Performance Gas Insulated Hv Transformer for Gis
PT Product High Performance Gas Insulated HV Transformer For Gis
Technical Parameters for JSQXF2-126 Voltage Transformer:
1 Rated primary voltage: 66kV, 110kV, 132kV, 150kV and 220kV and so on.
2 Rated secondary voltage: 0.1 /√3kV or 0.11 /√3kV.
3 Rated voltage of residual voltage winding: 0.1kV or 0.11kV.
4 Rated frequency and number of phases: 50Hz or 60Hz 3-phase.
5 Voltage ratio, maximum rated output and corresponding accuracy class please see table 1.
Table 1 Voltage Ratio, Maximum Rated Output and Corresponding Accuracy Class Table
PT Product High Performance Gas Insulated HV Transformer For Gis
Voltage Ratio (kV) | Accuracy Class and Rated Output (VA) | ||||
Secondary 1a-1n | Secondary 2a-2n | Residual da-dn | |||
0.2 | 0.5 | 0.2 | 0.5 | 3P | |
66 /√3/ 0.1 /√3-0.1 /√3-0.1 110 /√3/ 0.1 /√3-0.1 /√3-0.1 132 /√3/ 0.1 /√3-0.1 /√3-0.1 or 220 /√3/ 0.1 /√3-0.1 /√3-0.1 |
75 | 75 | 300 | ||
75 | 100 | ||||
200 | |||||
150 | 150 | ||||
300 |
6 Thermal limit output: 1500VA (for each secondary winding).
7 Except for limit loaded power factor from 0.8 (lag) to 1, the rest loaded power factor is 0.8 (lag).
8 Rated voltage factor and corresponding rated duration: 1.2 continuous, 1.5 30 s.
9 Rated pressure of SF6 (20): 0.40 ~ 0.58 MPa.
10 Minimum operating pressure of SF6 (20): 0.35 ~ 0.50 MPa.
Notes:
1 Those listed in the table above are the routine parameters, if there is any different parameter required, we
can design according to the technical parameters of the clients.
2 Detailed technical data and outline drawing are provided upon request.
Leading wire of secondary coil and leading wire of ground terminal of primary coil are connected with Phoenix special
terminal in the secondary terminal box via the terminal block cast as a whole with epoxy on the shell. It is more convenient
for operations such as plug-in, pull-out and wiring etc. The sealing performance meets the requirement of IP55.
The transformer can be installed horizontally or vertically.
Name: PT Product High Performance Gas Insulated HV Transformer For Gis |
|
For the low voltage products: |
5 -10 days |
For the medium voltage products: |
10 -15 days |
For the high voltage products: |
20 -30 days |
Payment: |
T/T or L/C |
Port: |
Guangzhou |
Packing: |
Wooden case |
We have a team who is in charge of packing.
The team consists of our skilful carpenters and experienced packing designers.
These enable our packing reasonable, safe and reliable.
Application:
1. Matching different sizes switchgears for voltage metering and protection or for control-circuit supply.
2. Power plant and power station.
3. All kinds of industrial area, such as factories, coal mine, subways and so on.
4. They also can be used in communities.
5. Especially suitable for medium voltage witchgears. image
Our advantages:
Quality Assurance
–From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
–With more than 30 years’ experience in power industry, VILLE brings you an optimized solution.
Global Service
–Wherever you are, VILLE global network will support and provide you with value.
Quick Response
–In response to your needs without delay, VILLE knows the value of your time.
Packaging Details: The accessories packed in plywood cases,the main body in nude.
Our Best Service For You
1. Pre sale service
A. Make technical solution
B. Send quotation, technical data sheet and drawing
C. Prepare power transmission plan, testing plan,and shipment plan
2. In sale service
A. Supervise the manufacturing schedule totally in accordance with the plan
B. Send photos to customer during every manufacturing process(hold point)
C. Inform the customer one week before testinng.
3. After sale service
A. Installation and commissioning, training the workers
B. Quick response within 12 hours any time
C. Provide 12 months gurantee period normally.
Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!
b057r03 fill sulfur hexafluoride _550kv Ultra High Voltage Hollow Core Porcelain Insulators
- Product Description
- Company Profile
economy serie liquefy sf6 가스 _12kv 24kv Bushing Current Transformer for Generator
Application:
The Outdoor Mounted Bushing Current Transformer is self contained and designed to be mounted externally over the high voltage terminal bushing of 66kv to 500kv Power transformers, 66kv to 500kv Power circuit breakers and 66kv to 500kv Cable terminators .
In most cases the BCT, with its ease of installation, is a reliable and economical solution when upgrading system protection and adding additional metering points.
When properly installed, the BCT can be used on higher system voltage levels while maintaining its own mere 600 Volt class rating. Its simple construction provides a low leakage product with virtually unlimited short circuit capabilities, far surpassing its stand alone wound-type counterpart
.
Construction:
The toroidal core is continuously tape wound using cold rolled grain oriented electrical grade silicon steel, which receives a full stress relief anneal after it is wound to its specified dimensions. The secondary winding is then wound of insulated copper magnet wire over the insulated core with the turns equally spaced around the core periphery. When taps are pulled, they are wound in a manner that assures a fully distributed winding between any connections. The coil is then fully encapsulated in an ANSI 70 (sky grey) resin system that has been developed and tested for outdoor use. The potting compound is U.V. stabilized, is flexible to allow for expansions caused by temperature variations from -50°C to +65°C, has good chemical resistance, high dielectric strength, rugged physical properties to endure mechanical shock, and overall excellent weather resistance.
Installation:
The BCT is custom designed to fit over any bushing. It can be supported by mounting clamps with standard bolt arm assembly & hardware for vertical adjustment. The placement of the bolts can be configured from either the ID or OD, and attached to the apparatus tank top. The number of clamps required is dependent on physical size and weight of the BCT. Custom mounting that permits attachment of clamping brackets directly to the bushing flange can also be provided – consult the factory for this option. In addition, a custom fitted ground shield may be installed on the top of the BCT and secured by the mounting clamps. This is highly recommended to direct any possible flash-over to the ground, thus bypassing the BCT preventing destruction of the BCT and connected equipment. Installation instructions are provided.
Handling and Storage:
For domestic shipments, the BCT is usually palletized with spacers between the units and the pallet to allow for lifting. Ideally they should be lifted using endless slings in a 2-point or 3-point arrangement, lifting by fork lift or overhead hoist, one unit at a time. Caution should be employed while moving to avoid damaging or chipping the insulation, and, any sudden impacts to the unit or the conduit box. The units are outdoor rated so they may be left outside as originally packaged, but they should preferably be stored indoors until ready for use. Pallets should not be stacked.
Size Selection:
Each unit is custom designed for its application. In addition to the current ratio, accuracy class and power frequency, some information regarding the equipment must be provided. Since there are countless configurations of equipment in the field, a site survey is recommended to aide with the proper sizing of the BCT. Often OEM outline drawings do not provide enough detail to determine this. We suggest submitting the original bushing drawing, digital photographs of each terminal and its immediate surroundings, and if possible some field measurements to locate potential obstacles such as conduit runs, oil gauges, manhole covers, lifting lugs, etc. Meramec Engineering will lay out the details using tools that will verify the size and strike clearances. Installation drawings will be provided for all custom mounted installations.
piccolo on-site gás sf6 _Rslh Series Sf6 Vacuuming Purification-Recovery and Refilling Device
Product Introduction
RSLH series SF6 gas vacuumizing purification-recovery and refilling device is mainly used for installation, commissioning and maintenance of SF6 circuit breaker,SF6 transformer,GIS and other SF6 Electrical products.
Technical Features
1.The design principle of freezing liquefaction method is adopted to improve the recovery efficiency.
2.Equipped with fully enclosed refrigeration compressor produced by Maneurop(French) or semi enclosed refrigeration compressor produced by Emerson(America).
3.Adopting semi enclosed SF6 compressor produced by Emerson.With fluorine resistance and no leakage,it is suitable for halogen gases.
4.With double container system,SF6 gas can be liquefied and filled into steel cylinder,and the filling capacity is not less than 50kg(using SF6 gas with high temperature and high pressure to force SF6 liquid with low temperature and low pressure to fill the cylinder).The filling capacity of single container recovery device is not less than 30kg.
5.Using the column SF6 liquid level meter with backlight,the indication is intuitive and accurate.
6.The liquid storage container is equipped with a built-in high-power SF6 vaporization electric heater. When in use,it can automatically control the temperature so that SF6 liquid can be fully vaporized.
7.The oil mist filtration system imported from the United States is adopted to ensure the oil content up to the standard.Compressor lubricating oil does not need to be added within one year,and the oil level does not drop.
8.The performance of molecular sieve drying system is very reliable.When molecular sieve is regenerated,it does not need to be disassembled,disassembled and replaced.Only the molecular sieve dryer needs self regeneration operation,then the drying performance can be restored as before.
9.Working principle of American Swagelok ball valves is adopted(American Swagelok original ball valves can also be optional),and sealing elements have the performance of automatic compensation.
10.Customized phase sequence protection device withstand voltage up to 500V.
11.Adoptiong three phase power supply(neutral line is not necessary),and the whole machine is equipped with leakage protector.
12.The vacuum pump can be equipped according to the user‘s requirement.(French Bush100m3/h,French Leybold D60C 60m3/h,Japanese brands or Chinese bipolar vacuum pump 15L/s ect)
13.Using pirani vacuum gauge with digital display.
Models For Selection
Item | Model | Size(mm) | Weight(kg) | Purpose |
1 | RSLH-12Q-4-40 | 1750×800×1550 | <650 | Suitable for Column circuit breaker, small switch box, ring main unit and container with small gas storage capacity (bellows) |
2 | RSLH-7Y-4-20 | 1500×700×1450 | <550 | Suitable for Column circuit breaker, small switch box, ring main unit and container with small gas storage capacity (bellows) |
3 | RSLH-12Y-15-100 | 1750×800×1650 | <800 | Suitable for electrical equipment manufacturing department, and also suitable for 35kV ~ 220kV GIS switch |
4 | RSLH-23Y-18-200 | 1870×1150×1700 | <1000 | Suitable for electrical equipment manufacturing department, and also suitable for 110kV ~500kV GIS switch |
5 | RSLH-36Y-18-300 | 1970×1150×1960 | <1200 | Suitable for electrical equipment manufacturing department, and also suitable for container with large gas storage capacity and 110kV ~800kV GIS switch |
sf6/n2 seperating unit integral sulfur hexafluoride _Fs6 66kv Voltage Class Gas Insulated Metal Enclosed Switchgear (GIS)
pplicable scope:
The Gas Insulated Metal Enclosed Switchgear (GIS) is a complete set of switchgear, which has circuit breaker, disconnector, earthing switch, current transformer, potential transformer, surge arrestor, busbar, ingoing and outgoing bushing or cable terminal all enclosed on a grounded metal tank and is filed with FS6 gas of specific pressure as the insukation medium. This product is applicable to three-phase, 50HZ, AC electric power system with the rated voltage of 72.5-252KV. Comply with IEC62271-203 “Gas insulated Metal Enclosed Switchgear for Rated Voltage of 50kV and Above”.